Eetess Power Equipment Co.,ltd

We develop creative, comprehensive, and sustainable engineering solutions for a future where society can thrive.

Battery Load Bank

Batteries are the core of critical DC power system, which can provide stable and uninterrupted backup power in various industry power utility, data center, telecom, oil and gas, railway, motive power and electric car industries. In the event of power failure in the power facilities or transformer substation, the backup batteries are the last guard of DC power system. It is crucial to identify batteries state of health and forcast failure before it is late .

Battery Load Bank is designed for battery bank acceptance testing, battery string capacity testing, DC power discharge testing, battery bank maintenance, and load bank tests for DC power system .

It can proceed discharge current by constant current and constant power mode for verifying the real capacity of batteries and forewarn battery SOH . High reliable and good heat dissipation ceramic resistor is used for Eetess load bank , which can ensure the device with steady performance and safe running.

Eetess power equipent co.,ltd , as battery load bank manufacturer , we will provide different device with different voltage and discharge current for 12V, 24V, 48V, 72V,80V,100V,125V, 220V,240V, 380V,480V. We can also provide one unit with a wide voltage range 10-800V for different application in various field.

Telecom and offshore Application

A stable and reliable telecom communication power system is crutial to ensuring safe and reliable running of base station communication system. Telecom commnication backup power is composd by 24V and 48V battery string. According to the maintenance regulations, the discharge capacity test is regularly carry out for checking the battery health state, which can maintenance of battery performance.

 

Eetess can offer LB series battery Load Bank for telecommnuication and offer application .They can provide efficient and accurate capacity test method for battery test and maintenance.

24V 48v
Battery Load Bank 24/48V

Batteries 24V and 48V are common battery voltage in telecom. Our KV-3900 series battery load bank can offer voltage level 24 and 48V for telecom application. Battery Discharge testing is a routine preventive maintenance for your DC system, which can forewarn battery bank death.

10-60V
Battery Load Bank 10-60V

Constant current battery load bank is used to battery capacity testing, battery discharge testing , battery acceptance . LB series battery load bank can provide 10-60V voltage range with different current for your 24V,48V battery system .

48V
Battery Load Unit 48V 200A

Battery Load Unit 48V 200A is a common type for battery system in telecom . It has a LCD sceen to display the discharge voltage , discharge time, discharge current and battery capacity. The device is compact and portable, which is also easy for operating by touch screen.

48V
Battery DC Load Bank 48V

Eetess can provide a full series of customized DC load banks with many different models. They covers a wide voltage range which is widely used on various fields . With optional cell voltage monitor (CVM), discharge data of each cell battery can be monitored directly connecting with battery load bank . The data software can provide user with data report and data graph.

Data Center Application

Large-scale enterprises create and transmit massive amounts of information and data, such as communication operations and the Internet, need to build their own data centers.

Date information safely transmit and storage are our top priority concerning. The stable operation of large computer rooms and data center means the huge power supply guarantee facilities. Your critical power system highly live on the performance to battery string . As an important component of the uninterruptible power supply in data center, it is essential to carry on preventive maintenance for battery strings to ensure stable and safe running when they are needed. Eetess offers battery test equipment and battery discharge tester

10-60V
Battery Discharger 10-60V

Discharge testing is an essential preventative maintenance for all critical backup battery. For data center, we have load bank tester 24V & 48V and other load bank with high dishcarge current .

380V
Battery Load Unit 380V

Battery Load Unit 380V is applicable for the UPS system in the data center . Eetess can provide a series of battery load banks with different discharge current to meet your different application .

480V
Battery Load Bank, Battery Monitor

Battery Load Bank Tester can monitor the battery voltage , discharge current , discharge capacity during the discharge. Equipped with cell voltage monitor , it can monitor discharge events in real time, record data, analysis and create reports.

10-800V
Battery Discharge Load

Eetess can provides a full series of customzied constance current battery load banks with many different models. They covers a wide voltage range from 10V to 800V which is widely used on various fields .

Power Utility Application

DC system is an important system of power utility. Battery is an important part of DC system, the safe and stable running of batteries is directly related to equipment safety of power system and stable operation of power grid . To ensure your backup power system can work normally when there is power outage.

Eetess suppliers customized DC Load Bank for your DC system 110V (125V) and 220V (240V).  110V and 220V  Battery Load Bank

125V
Battery Load Bank 125V

Battery Load Bank 125V 100A is designed for proceeding the discharge test in the DC power system 110V . Battery Discharge testing is only effective method to verify the state-of-heath of the battery .

220V
Battery Load Bank 220V

Battery Load Bank 220V is designed for performing discharge testing which is the only verifiable method to determine actual capacity of battery systems. When you proceed the loading test , discharge testing , acceptance testing, battery capacity testing, Eetess can provides a full series of customzied DC load banks with many different models.

110v 220V
Battery Load Bank 110v 220V

Eetess can provide a full series of customized DC load banks with many different models. They covers a wide voltage range which is widely used on various fields . With optional cell voltage monitor (CVM), discharge data of each cell battery can be monitored directly connecting with battery load bank .

10-800V
Battery Discharge Load

Eetess can provides a full series of customzied constance current battery load banks with many different models. They covers a wide voltage range from 10V to 800V which is widely used on various fields .

Motive Power , Forklift and Golfcart Application

Motive power battieries are widely used in forklifts and automobile, golf cart . This traction batteries as startup power are very popular batteries with an extremely high power density.  For the inspection of battery real capacity, our type battery discharge capacity tester can be customized, which covers full range of common battery strings in traction batteries.

For charging and activting power batteries, Eetess can offer battery activationg for single battery and battery strings. Our battery activator can effectively active the sulfuration materials on battery electrode plate and restore the lag batteries.

10-60V
Battery Load Bank 10-60V

Battery Load Bank 10-60V is a portable test equipment. Load testing is popular in the motive power field to evaluate forklift and traction batteries,which is a routine preventive maintenance to forewarn battery bank death.

10-300V
Battery Discharge Load

Eetess can provide a full series of customized DC load banks with many different models. They covers a wide voltage range which is widely used on various fields . With optional cell voltage monitor (CVM), discharge data of each cell battery can be monitored directly connecting with battery load bank .

10-60V
Battery Charger Discharger 10-60V

Load testing is increasingly popular in the motive power field to evaluate forklift and traction batteries . Battery Charger Discharger can proceed the charging , discharging and activating for battery strings

10-125V
Battery Charger Discharger 10-125v

Battery charger discharger is a multi-function comprehensive tester which is not only a battery charger and battery discharger, but only a battery activator . Type 10-125V battery regeneration is applicable in motive batteries .

pt_PTPortuguese (Portugal)